Коды ошибок Konica Minolta Bizhub C224/284/364 (C5601 - C6913)

Список включает ошибки моделей C224/284/364 и C224e/284e/364e 

 

  • Code: C5601

Description:

Engine control malfunction

Engine control malfunction is detected with port monitor control.

Remedy:

  1. Check the connectors on the PRCB for proper connection and correct or change as necessary.
  2. Rewrite the firmware.
  3. Replace PRCB.

 

  • Code: C6001

Description:

DF related configuration error 1

Inconsistency in the configuration with the installed DF is detected on the main body.

Remedy:

  1. Check the type of the installed DF and replace it if it is a wrong one. 
  2. Check to see if the correct firmware is installed and rewrite with the correct one as necessary. 
  3. Correct the harness connection between DFCB and DSIPB if faulty. 
  4. Correct the harness connection between DSIPB and MFPB if faulty. 
  5. Replace DFCB. 
  6. Replace DSIPB. 
  7. Replace MFPB.

 

  • Code: C6002

Description:

DF related configuration error 2

Inconsistency in the configuration with the installed DF is detected on the DF.

Remedy:

  1. Check the type of the installed DF and replace it if it is a wrong one.
  2. Correct the harness connection between DFCB and DSIPB if faulty. 
  3. Check the connectors of the dual scan image processing board (DSIPB) for proper connection, and correct as necessary. (Direction of the point of contact and connection state of the flat cable in particular)

 

  • Code: C6102

Description:

Drive system home sensor malfunction

• The scanner home sensor (PS201) is unable to detect the scanner located at its home position.

• The scanner home sensor (PS201) is unable to detect a scanner even when the scanner motor has been driven to move the scanner over the maximum travelling distance.

• The scanner home sensor (PS201) detects the scanner when the scanner has moved the maximum travelling distance from the position, at which it blocks the scanner home sensor (PS201).

Remedy:

  1. Correct or change the scanner drive (pulley, gear, belt) if it is faulty.
  2. Correct the scanner motor set screw if loose.
  3. Adjust [Image Position Leading Edge] and [Feed Direction Adjustment]. 
  4. Check the connector between M201-SCDB PJ4 for proper connection and correct as necessary. 
  5. Check the connector between PS201-SCDB PJ6 for proper connection and correct as necessary. 
  6. Check the connector between SCDB PJ2-PRCB CN43 for proper connection and correct as necessary. 
  7. PS201 I/O check, sensor check SCDB PJ6-3 (ON) 25-P. 
  8. M201 operation check SCDB PJ4-1 to 4 26-P.
  9. Replace SCDB. 
  10. Replace PRCB.

 

  • Code: C6103

Description:

Slider over running

The scanner home sensor (PS201) detects the scanner at its home position during a period of time that begins with the time when a prescan command and a scan preparation command are executed and ends when a home return command is executed.

Remedy:

  1. Correct or change the scanner drive (pulley, gear, belt) if it is faulty.
  2. Correct the scanner motor set screw if loose.
  3. Adjust [Image Position Leading Edge] and [Feed Direction Adjustment].
  4. Check the connector between M201-SCDB PJ4 for proper connection and correct as necessary.
  5. heck the connector between PS201-SCDB PJ6 for proper connection and correct as necessary. 
  6. Check the connector between SCDB PJ2-PRCB CN43 for proper connection and correct as necessary.
  7. PS201 I/O check, sensor check SCDB PJ6-3 (ON) 25-P.
  8. M201 operation check SCDB PJ4-1 to 4 26-P.
  9. Replace SCDB. 
  10. Replace PRCB.

 

  • Code: C6104

Description:

Back side cleaning home sensor abnormality (initial)

<When DF-701 is installed>

• The CIS cleaning sensor (PS7) does not change from H to L even after the lapse of a given period of time after the home position detecting operation is started at the initial operation.

• The CIS cleaning sensor (PS7) does not change from L to H even after the lapse of a given period of time after the home position detecting operation is started at the initial operation.

Remedy:

  1. Check if the opening and closing guide is firmly closed. 
  2. Check the connector between M5-DFCB J9 for proper connection, and correct as necessary. 
  3. Check the connector of M5 for proper drive coupling, and correct as necessary. 
  4. Check the connector between PS7-DFCB J13 for proper connection, and correct as necessary.
  5. PS7 I/O check, sensor check DRCB J13-3 (ON) DF-701 1-G. 
  6. M5 operation check DRCB J9-1 to 4 DF-701 6-G.
  7. 7 Replace M5. 
  8. Replace DFCB.

 

  • Code: C6105

Description:

Back side cleaning home sensor abnormality (normal)

<When DF-701 is installed> At the time of operation other than the initial operation, the CIS cleaning sensor (PS7) error is detected.

Remedy:

  1. Check if the opening and closing guide is firmly closed.
  2. Check the connector between M5-DFCB J9 for proper connection, and correct as necessary.
  3. Check the connector of M5 for proper drive coupling, and correct as necessary.
  4. Check the connector between PS7-DFCB J13 for proper connection, and correct as necessary.
  5. PS7 I/O check, sensor check DRCB J13-3 (ON) DF-701 1-G.
  6. M5 operation check DRCB J9-1 to 4 DF-701 6-G.
  7. Replace M5.
  8. Replace DFCB.

 

  • Code: C6704

Description:

Image input time out

Image data is not input from the scanner to the MFP board (MFPB).

Remedy:

  1. Select [Service Mode] - [State Confirmation] - [Memory/HDD Adj.] - [Memory Bus Check] - [Scanner - Memory], and conduct the memory bus function.
  2. Check the connectors between scanner section and MFPB for proper connection and correct as necessary.
  3. Replace MFPB. 4 Replace CCDB.

 

  • Code: C6751

Description:

CCD clamp/gain adjustment failure

• The adjustment value is 0 or 255 during a CCD clamp adjustment.

• The peak value of the output data is 64 or less during a CCD gain adjustment.

Remedy:

  1. Check the connector between CCDB PJ3-MFPB PJ01 for proper connection and correct as necessary.
  2. heck for possible extraneous light and correct as necessary. 
  3. Clean the lens, mirrors, CCD surface, and shading sheet if dirty.
  4. Correct reflective mirror of the scanner if faulty, or change scanner mirror.
  5. Replace CCDB.
  6. Replace MFPB.

 

  • Code: C6752

Description:

ASIC clock input error (front side)

When starting the machine, verification on reading and writing the predetermined value for image processing ASIC on CCD board (CCDB) was conducted, and verification failure was detected.

Remedy:

  1. Correct the harness connection of CCDB if faulty.
  2. Replace CCDB.
  3. Replace MFPB.

 

  • Code: C6753

Description:

ASIC clock input error (back side)

<When DF-701 is installed> When starting the machine, verification on reading and writing the predetermined value for image processing ASIC on dual scan image processing board (DSIPB) was conducted, and verification failure was detected.

Remedy:

  1. Correct the harness connection between DF and DSIPB if faulty.
  2. 2 Correct the harness connection between DSIPB and MFPB if faulty. 
  3. Replace CIS. 
  4. Replace DSIPB.
  5. Replace MFPB.

 

  • Code: C6754

Description:

CIS clamp adjustment failure

<When DF-701 is installed> After the gain adjustment is performed at the start-up, the CIS clamp adjustment value is too high or too low.

Remedy:

  1. Correct the harness connection between CIS and DSIPB if faulty. 
  2. Correct the harness connection between CIS and CISPU if faulty. 
  3. Check for possible extraneous light and correct as necessary. 
  4. Clean the back side reading glass and the shading sheet if dirty. 
  5. Replace CIS. 
  6. Replace DSIPB.
  7. Replace CISPU.
  8. Replace MFPB.

 

  • Code: C6755

Description:

CIS gain adjustment failure

<When DF-701 is installed> After the gain adjustment is performed at the start-up, the peak value of the output data is lower than a given value.

Remedy:

  1. Correct the harness connection between CIS and DSIPB if faulty.
  2. Correct the harness connection between CIS and CISPU if faulty.
  3. Check for possible extraneous light and correct as necessary.
  4. Clean the back side reading glass and the shading sheet if dirty.
  5. Replace CIS.
  6. Replace DSIPB.
  7. Replace CISPU.
  8. Replace MFPB.

 

  • Code: C6756

Description:

CCD power-supply voltage malfunction

Power is not supplied to CCD after the lapse of a given period of time after the main power switch or sub power key is turned ON or the machine recovers from the sleep mode.

Remedy:

  1. Correct the harness connection between CCDB and SCDB if faulty.
  2. Correct the harness connection between SCDB and DCPU if faulty.
  3. Replace CCDB.
  4. Replace SCDB.
  5. Replace DCPU.

 

  • Code: C6901

Description:

DSC board mount failure 1

When MFP detects that DSC board/1 (front side) is not properly installed.

Remedy:

  1. Correct the harness connection of DSCB/1 if faulty.
  2. Replace DSCB/1.
  3. Replace MFPB

 

  • Code: C6902

Description:

DSC board bus check NG1-1

When DSC bus check (front side) detects an error.

Remedy:

  1. Correct the harness connection of DSCB/1 if faulty.
  2. Replace DSCB/1.
  3. Replace MFPB

 

  • Code: C6903

Description:

DSC board bus check NG1-2

When DSC bus check (front side) detects an error.

Remedy:

  1. Correct the harness connection of DSCB/1 if faulty.
  2. Replace DSCB/1.
  3. Replace MFPB

 

  • Code: C6911

Description:

DSC board mount failure 2

<When DF-701 is installed> When MFP detects that DSC board/2 (back side) is not properly installed.

Remedy:

  1. Correct the harness connection of DSCB/2 if faulty.
  2. Correct the harness connection of DSIPB if faulty.
  3. Replace DSCB/2.
  4. Replace DSIPB.
  5. Replace MFPB.

 

  • Code: C6912

Description:

DSC Bus check NG2-1

<When DF-701 is installed> When MFP detects that DSC board/2 (back side) is not properly installed.

Remedy:

  1. Correct the harness connection of DSCB/2 if faulty.
  2. Correct the harness connection of DSIPB if faulty.
  3. Replace DSCB/2.
  4. Replace DSIPB.
  5. Replace MFPB.

 

  • Code: C6913

Description:

DSC Bus check NG2-2

<When DF-701 is installed> When MFP detects that DSC board/2 (back side) is not properly installed.

Remedy:

  1. Correct the harness connection of DSCB/2 if faulty. 
  2. Correct the harness connection of DSIPB if faulty. 
  3. Replace DSCB/2. 
  4. Replace DSIPB. 
  5. Replace MFPB.