Коды ошибок Konica Minolta Bizhub C220/280/360

Code: C0000

Description:

Main Motor malfunction
•The Main Motor (M1) Lock signal remains HIGH for a continuous 1-sec. period at any time 1 sec. after the Main Motor has started turning.

Remedy:

1 Check M1 connectors for proper connection and correct as necessary. 2 Check M1 for correct drive coupling and correct as necessary. 3 M1 operation check. 4 Change PWB-A. 5 Change PU1.

 

Code: C0044

Description:

ADF Cooling Fan Failure (Only when the optional DF is mounted)
The ADF Fan Motor Lock signal remains set to H for a set period of time while the EDH Fan Motor is turning.

Remedy:

 Check the motor connectors for paper connection, and correct as necessary. 2 Check the fan for possible overload, and correct as necessary. 3 M3-ADF operation check. 4 Replace PBA-CONT.

 

Code: C0045

Description:

Fusing Cooling Fan Motor malfunction
The Fusing Cooling Fan Motor (M3) Lock signal remains HIGH for a continuous 1-sec. period while the Fusing Cooling Fan Motor is turning at full speed or decelerated speed.

Remedy:

1 Check M3 connectors for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M3 operation check 4 Change PWB-A. 5 Change PU1.

 

Code: C004E

Description:

Power Supply Cooling Fan Motor malfunction
The Power Supply Cooling Fan Motor (M4) Lock signal remains HIGH for a continuous 1-sec. period while the Power Supply Cooling Fan Motor Remote signal remains ON (for full-speed rotation) or OFF (for decelerated-speed rotation).

Remedy:

1 Check M4 connectors for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 M4 operation check 4 Change PWB-A. 5 Change PU1.

 

Code: C0070

Description:

Toner Replenishing Motor malfunction
The Toner Bottle Home Position Sensor (PC7) outputs a HIGH signal for a continuous 3.5-sec. period while the Toner Bottle is turning.
The Toner Bottle Home Position Sensor (PC7) outputs a LOW signal for a continuous 2-sec. period while the Toner Bottle is turning.

Remedy:

1 Check M6 connectors for proper connection and correct as necessary. 2 Check M6 for correct drive coupling and correct as necessary. 3 M6 operation check 4 PC7 sensor check 5 Change PWB-A. 6 Change PU1.

 

Code: C0210

Description:

Abnormal image transfer voltage
The image transfer voltage remains more than 100 V continuously for a given period of time while the PC Drum remains stationary.

Remedy:

1 Check the Image Transfer Roller for installation. 2 Change HV1. 3 Change PWB-A.

 

Code: C03FF

Description:

Faulty Model Setting

“Model Setting” of “Adjust” available from the Service mode is incorrectly set.

 

Code: C0500

Description:

 

Warm-up failure

- The surface temperature of the Fusing Roller does not reach a given level even after the lapse of a given period of time during a warm-up cycle.

Remedy:

1 Check that the Fusing Roller Heater Lamp (H1) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 2 Check that the Fusing Roller Sub Heater Lamp (H2) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 3 Check the Fusing Roller Thermostat (TS1) for operation. <Check procedure> Check the resistance of TS1. TS1 is open-circuited if its resistance is infinity. 4 Check the Fusing Unit Interlock Switch (S2) for operation. <Check procedure> Check continuity across the following terminals when S2 is ON. • Across S2-1A and S2-1B • Across S2-2A and S2-2B 5 Check the Fusing Roller Thermistor (TH1) and Fusing Roller Sub Thermistor (TH2) for installation and correct or clean as necessary. 6 Check the Fusing Roller Thermistor (TH1) for operation. <Check procedure> Disconnect CN15 (4P) and check the resistance across CN15-2 and 3 on the Thermistor side. TH1 is open-circuited if the resistance is infinity. 7 Check the Fusing Roller Sub Thermistor (TH2) for operation. <Check procedure> Disconnect CN22 (4P) and check the resistance across CN22-2 and 3 on the Thermistor side. TH2 is open-circuited if the resistance is infinity. 8 Check the Fusing Roller Heater Lamp (H1) for continuity and correct or replace as necessary. 9 Check the Fusing Roller Sub Heater Lamp (H2) for continuity and correct or replace as necessary. 10 Change PU1. 11 Change PWB-A.

 

Code: C0501

Description:

Warm-up failure 2 (for the model having two Fusing Roller Heater Lamps)

- The Fusing Roller Sub Thermistor does not detect a predetermined temperature within 30 sec. after a warm-up cycle has been started and thus the warm-up cycle is not completed.

- The surface temperature of the Fusing Roller does not reach a given level even after the lapse of a given period of time during a warm-up cycle.

Remedy:

1 Check that the Fusing Roller Heater Lamp (H1) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 2 Check that the Fusing Roller Sub Heater Lamp (H2) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 3 Check the Fusing Roller Thermostat (TS1) for operation. <Check procedure> Check the resistance of TS1. TS1 is open-circuited if its resistance is infinity. 4 Check the Fusing Unit Interlock Switch (S2) for operation. <Check procedure> Check continuity across the following terminals when S2 is ON. • Across S2-1A and S2-1B • Across S2-2A and S2-2B 5 Check the Fusing Roller Thermistor (TH1) and Fusing Roller Sub Thermistor (TH2) for installation and correct or clean as necessary. 6 Check the Fusing Roller Thermistor (TH1) for operation. <Check procedure> Disconnect CN15 (4P) and check the resistance across CN15-2 and 3 on the Thermistor side. TH1 is open-circuited if the resistance is infinity. 7 Check the Fusing Roller Sub Thermistor (TH2) for operation. <Check procedure> Disconnect CN22 (4P) and check the resistance across CN22-2 and 3 on the Thermistor side. TH2 is open-circuited if the resistance is infinity. 8 Check the Fusing Roller Heater Lamp (H1) for continuity and correct or replace as necessary. 9 Check the Fusing Roller Sub Heater Lamp (H2) for continuity and correct or replace as necessary. 10 Change PU1. 11 Change PWB-A.

 

Code: C0510

Description:

Fusing failure (abnormally low fusing temperature)

- The temperature detected by the Fusing Roller Thermistor remains lower than 120°C (105°C for the model having two Fusing Roller Heater Lamps) for a given period of time during the standby state.

- The temperature detected by the Fusing Roller Thermistor remains lower than 120°C (105°C for the model having two Fusing Roller Heater Lamps) for a given period of time during a print cycle.

Remedy:

1 Check that the Fusing Roller Heater Lamp (H1) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 2 Check that the Fusing Roller Sub Heater Lamp (H2) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 3 Check the Fusing Roller Thermostat (TS1) for operation. <Check procedure> Check the resistance of TS1. TS1 is open-circuited if its resistance is infinity. 4 Check the Fusing Unit Interlock Switch (S2) for operation. <Check procedure> Check continuity across the following terminals when S2 is ON. • Across S2-1A and S2-1B • Across S2-2A and S2-2B 5 Check the Fusing Roller Thermistor (TH1) and Fusing Roller Sub Thermistor (TH2) for installation and correct or clean as necessary. 6 Check the Fusing Roller Thermistor (TH1) for operation. <Check procedure> Disconnect CN15 (4P) and check the resistance across CN15-2 and 3 on the Thermistor side. TH1 is open-circuited if the resistance is infinity. 7 Check the Fusing Roller Sub Thermistor (TH2) for operation. <Check procedure> Disconnect CN22 (4P) and check the resistance across CN22-2 and 3 on the Thermistor side. TH2 is open-circuited if the resistance is infinity. 8 Check the Fusing Roller Heater Lamp (H1) for continuity and correct or replace as necessary. 9 Check the Fusing Roller Sub Heater Lamp (H2) for continuity and correct or replace as necessary. 10 Change PU1. 11 Change PWB-A.

 

Code: C0511

Description:

Fusing failure (abnormally low fusing temperature 2)

The temperature detected by the Fusing Roller Sub Thermistor remains lower than 105°C for a given period of time during the standby state.

The temperature detected by the Fusing Roller Sub Thermistor remains lower than 105°C for a given period of time during a print cycle.

Remedy:

 

 

1 Check that the Fusing Roller Heater Lamp (H1) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 2 Check that the Fusing Roller Sub Heater Lamp (H2) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 3 Check the Fusing Roller Thermostat (TS1) for operation. <Check procedure> Check the resistance of TS1. TS1 is open-circuited if its resistance is infinity. 4 Check the Fusing Unit Interlock Switch (S2) for operation. <Check procedure> Check continuity across the following terminals when S2 is ON. • Across S2-1A and S2-1B • Across S2-2A and S2-2B 5 Check the Fusing Roller Thermistor (TH1) and Fusing Roller Sub Thermistor (TH2) for installation and correct or clean as necessary. 6 Check the Fusing Roller Thermistor (TH1) for operation. <Check procedure> Disconnect CN15 (4P) and check the resistance across CN15-2 and 3 on the Thermistor side. TH1 is open-circuited if the resistance is infinity. 7 Check the Fusing Roller Sub Thermistor (TH2) for operation. <Check procedure> Disconnect CN22 (4P) and check the resistance across CN22-2 and 3 on the Thermistor side. TH2 is open-circuited if the resistance is infinity. 8 Check the Fusing Roller Heater Lamp (H1) for continuity and correct or replace as necessary. 9 Check the Fusing Roller Sub Heater Lamp (H2) for continuity and correct or replace as necessary. 10 Change PU1. 11 Change PWB-A.

 

Code: C0520

Description:

Fusing failure (abnormally high fusing temperature 2)

 The temperature detected by the Fusing Roller Thermistor remains higher than 240°C for a given period of time.

Remedy:

1 Check that the Fusing Roller Heater Lamp (H1) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 2 Check that the Fusing Roller Sub Heater Lamp (H2) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 3 Check the Fusing Roller Thermostat (TS1) for operation. <Check procedure> Check the resistance of TS1. TS1 is open-circuited if its resistance is infinity. 4 Check the Fusing Unit Interlock Switch (S2) for operation. <Check procedure> Check continuity across the following terminals when S2 is ON. • Across S2-1A and S2-1B • Across S2-2A and S2-2B 5 Check the Fusing Roller Thermistor (TH1) and Fusing Roller Sub Thermistor (TH2) for installation and correct or clean as necessary. 6 Check the Fusing Roller Thermistor (TH1) for operation. <Check procedure> Disconnect CN15 (4P) and check the resistance across CN15-2 and 3 on the Thermistor side. TH1 is open-circuited if the resistance is infinity. 7 Check the Fusing Roller Sub Thermistor (TH2) for operation. <Check procedure> Disconnect CN22 (4P) and check the resistance across CN22-2 and 3 on the Thermistor side. TH2 is open-circuited if the resistance is infinity. 8 Check the Fusing Roller Heater Lamp (H1) for continuity and correct or replace as necessary. 9 Check the Fusing Roller Sub Heater Lamp (H2) for continuity and correct or replace as necessary. 10 Change PU1. 11 Change PWB-A.

 

Code: C0521

Description:

Fusing failure (abnormally high fusing temperature 2)
The temperature detected by the Fusing Roller Sub Thermistor remains higher than 240°C for a given period of time.

Remedy:

1 Check that the Fusing Roller Heater Lamp (H1) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 2 Check that the Fusing Roller Sub Heater Lamp (H2) turns ON when the Power Switch is turned ON and correct or replace the lamp as necessary. 3 Check the Fusing Roller Thermostat (TS1) for operation. <Check procedure> Check the resistance of TS1. TS1 is open-circuited if its resistance is infinity. 4 Check the Fusing Unit Interlock Switch (S2) for operation. <Check procedure> Check continuity across the following terminals when S2 is ON. • Across S2-1A and S2-1B • Across S2-2A and S2-2B 5 Check the Fusing Roller Thermistor (TH1) and Fusing Roller Sub Thermistor (TH2) for installation and correct or clean as necessary. 6 Check the Fusing Roller Thermistor (TH1) for operation. <Check procedure> Disconnect CN15 (4P) and check the resistance across CN15-2 and 3 on the Thermistor side. TH1 is open-circuited if the resistance is infinity. 7 Check the Fusing Roller Sub Thermistor (TH2) for operation. <Check procedure> Disconnect CN22 (4P) and check the resistance across CN22-2 and 3 on the Thermistor side. TH2 is open-circuited if the resistance is infinity. 8 Check the Fusing Roller Heater Lamp (H1) for continuity and correct or replace as necessary. 9 Check the Fusing Roller Sub Heater Lamp (H2) for continuity and correct or replace as necessary. 10 Change PU1. 11 Change PWB-A.

 

Code: C0650

Description:

Faulty Scanner Home Position Sensor
The Scanner Home Position Sensor (PC10) does not go from HIGH to LOW when the Scanner Motor (M5) is energized for a given number of steps after the sequence to bring the Scanner back to its home position has been started at the end of a scan motion and during re-shading.
The Scanner Home Position Sensor (PC10) does not go from LOW to HIGH when the Scanner Motor (M5) is energized for a given number of steps after a scan motion has been started at the end of a Scanner Home Position Sensor home check scan motion and during re-shading.

Remedy:

1 Check M5 connectors for proper connection and correct as necessary. 2 Check M5 for correct drive coupling and correct as necessary. 3 M5 operation check 4 Scanner operation check 5 PC10 sensor check 6 Change PWB-C/C.

 

Code: C0B60

Description:

Bin Switching Motor malfunction (Only when the optional JS is mounted)
- Refer to the option service manual (JS-503) for details.

Remedy:

 

 

 

Code: C0B80

Description:

Shift Motor malfunction (Only when the optional SF is mounted)
- Refer to the option service manual (SF-501) for details.

 

Code: C0F32

Description:

Faulty ATDC Sensor
- The measurement taken by the ATDC Sensor (UN1) at a time 2.0 sec. after the Main Motor (M1) has started turning is less than 5% (greater than 4.63 V).
- The measurement taken by the ATDC Sensor (UN1) at a time 2.0 sec. after the Main Motor (M1) has started turning is 19% or more (1.41 V or less).

Remedy:

1 Check to see if developer is available. 2 Check the ATDC Sensor connectors for proper connection and correct as necessary. 3 Change UN1. 4 Run ?gATDC Auto Adjust. 5 Change PWB-A. 6 Change PU1.

 

Code: C0F33

Description:

Improperly adjusted ATDC Sensor
- The adjustment of the ATDC control voltage is not completed within 1 sec. after sampling has started of the ATDC Sensor (UN1) as part of an operation of ATDC Sensor Automatic Adjustment.
- The ATDC Sensor control voltage falls outside the range of 5.39 V to 8.15 V during an operation of ATDC Sensor Automatic Adjustment.

Remedy:

 

Code: C1038

Description:

Engine connection failure
Master Board (PWB-A) to Control Board (PWB-C/C) connection failure
- There is no acknowledge signal transmitted from the Master Board (PWB-A) to Control Board (PWB-C/C) for 1.5 sec. or more.
- An error command signal is transmitted from the Control Board (PWB-C/C) to Master Board (PWB-A).
- An error status signal is transmitted from the Master Board (PWB-A) to Control Board (PWB-C/C).

Remedy:

1 Turn OFF and ON the Power Switch. 2 Check the PWB-A connectors for proper connection and correct as necessary. 3 Check the PWB-C/C connectors for proper connection and correct as necessary. 4 Check for proper connection between PWB-A and PWB-C/C and correct as necessary. 5 Change PWB-A. 6 Change PWB-C/C.

 

Code: C1200

Description:

Faulty ASIC/memory
ASIC/memory (for image and control) fault
A write or read error occurs with SRAM on the Control Board (PWB-C/C).

Remedy:

1 Turn OFF and ON the Power Switch. 2 Check memory on PWB-C/C for connection and correct as necessary. 3 Change PWB-C/C.

 

Code: C1300

Description:

Polygon Motor malfunction
-Startup failure
- Lock signal fault: Unstable after the first Lock signal has been detected
- Lock signal fault: Lock signal out-of-timing

Remedy:

1 Turn OFF and ON the Power Switch. 2 Check for proper connection between the PH Unit and Master Board and correct as necessary. 3 Change the PH Unit. 4 Change PWB-A.

 

Code: C133B

Description:

Communication with option error
- It is not possible to communicate with the Printer Board within a predetermined period of time during a print cycle.

Remedy:

 

Code: C133D

Description:

ROM check error
- An error is detected of the flash ROM chip on the Fax Board when the Power Switch is turned ON.

 

Code: C13F0

Description:

Faulty HSYNC
Laser scanning system malfunction
- The SOS Sensor does not detect a rising edge of SOS within a given period of time after the Polygon Motor (M2) has started turning and a laser output has been started.
- The SOS Sensor detects no rising edges of SOS while VIA (image area control) is ON.

Remedy:

1 Turn OFF and ON the Power Switch. 2 Check for proper connection between the PH Unit and Master Board and correct as necessary. 3 Change the PH Unit. 4 Change PWB-A.

 

Code: C1468

Description:

Faulty Parameter Chip
Parameter Chip fault
- Data cannot be written in Parameter Chip.
- Data stored in Parameter Chip is wrong.

Remedy:

1 Turn OFF the Power Switch and unplug the power cord. Then, plug in the power cord and turn ON the Power Switch again. 2 Check Parameter Chip (U16) on PWB-C/C for proper connection and correct as necessary. 3 Change PWB-A. 4 Change Parameter Chip.

 

Code: C14A3

Description:

IR fluorescent lamp fault
The Exposure Lamp (LA2) of the Scanner fails to turn ON.
- The intensity of the Exposure Lamp is a predetermined value or less during shading and re-shading.

Remedy:

1 Check that the Exposure Lamp (LA2) turns ON when the Power Switch is turned ON and correct or replace as necessary. 2 Check connectors on PU2 for proper connection and correct as necessary. 3 Check connectors on PWB-J for proper connection and correct as necessary. 4 Change PWB-C/C.

 

Code: C3FFF

Description:

Flash ROM error