Коды ошибок Konica Minolta Bizhub C203/253/353 (C0001 - C255C)

 

Code: C0001

 

Description:

LCT connection failed

 

Code: C0202

 

Description:

Tray 1 feeder up/down abnormality
• The paper feed tray 1 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.

Remedy:

1 Check the M8 connector for proper connection and correct as necessary. 2 Check the connector of M8 for proper drive coupling and correct as necessary. 3 PS8 I/O check, sensor check. 4 M8 operation check. 5 Change M8. 6 Change PRCB.

 

Code: C0204

 

Description:

Tray 2 feeder up/down abnormality
• The paper feed tray 2 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.

Remedy:

1 Check the M9 connector for proper connection and correct as necessary. 2 Check the connector of M9 for proper drive coupling and correct as necessary. 3 PS15 I/O check, sensor check. 4 M9 operation check. 5 Change M9. 6 Change PRCB.

 

Code: C0206

 

Description:

Tray 3 feeder up/down abnormality

 

Code: C0208

 

Description:

Tray 4 feeder up/down abnormality

 

Code: C0209

 

Description:

LCT elevator motor malfunction

 

Code: C0210

 

Description:

LCT ascent motion failure

 

Code: C0211

 

Description:

Manual feed up/down abnormality
• The manual lift-up position sensor is not unblocked even when the transport motor has turned for a given number of pulses after the sequence to move the paper lifting plate from the standby position to the feed position was started.
• The manual lift-up position sensor is not blocked even when the transport motor has turned for a given number of pulses after the sequence to move the paper lifting plate from the feed position to the standby position was started.

Remedy:

1 Check the M1 connector for proper connection and correct as necessary. 2 Check the connector of M1 for proper drive coupling and correct as necessary. 3 PS17 I/O check, sensor check. 4 SL1 operation check. 5 M1 operation check. 6 Change SL1. 7 Change M1. 8 Change PRCB.

 

Code: C0212

 

Description:

LCT ejection failure

 

Code: C0213

 

Description:

LCT shift gate malfunction

 

Code: C0214

 

Description:

LCT shifting failure

 

Code: C0215

 

Description:

LCT shift motor malfunction

 

Code: C0301

 

Description:

Suction fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.

Remedy:

1 Check the FM8 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM8 operation check. 4 Change FM8. 5 Change PRCB.

 

Code: C0351

 

Description:

Paper cooling fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.

Remedy:

1 Check the FM7 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM7 operation check. 4 Change FM7. 5 Change PRCB.

 

Code: C1004

 

Description:

FNS communication error

 

Code: C1182

 

Description:

Shift motor mechanism failure

 

Code: C1183

 

Description:

Finishing option elevator drive malfunction

 

Code: C1190

 

Description:

Finishing option aligning bar moving mechanism malfunction 1

 

Code: C1191

 

Description:

Finishing option aligning bar moving mechanism malfunction 2

 

Code: C11A0

 

Description:

Paper holding drive failure

Remedy:

 

 

Code: C11A1

 

Description:

Finishing option exit roller pressure/retraction failure

 

Code: C11A2

 

Description:

Saddle exit roller pressure/retraction failure

 

Code: C11A3

 

Description:

Shutter drive failure

 

Code: C11A4

 

Description:

Saddle exit motor failure

 

Code: C11A5

 

Description:

Saddle in & out guide motor failure

 

Code: C11A6

 

Description:

Saddle layable guide drive failure

 

Code: C11B0

 

Description:

Finishing option stapler unit CD drive failure

 

Code: C11B2

 

Description:

Finishing option stapling mechanism malfunction 1

 

Code: C11B5

 

Description:

Side staple 1 drive failure

 

Code: C11B6

 

Description:

Side staple 2 drive failure

 

Code: C11C0

 

Description:

Punch motor malfunction

 

Code: C11D0

 

Description:

Crease motor drive failure

 

Code: C11E0

 

Description:

Route switch malfunction

 

Code: C1301

 

Description:

Finishing option cooling fan motor failure

 

Code: C2151

 

Description:

Secondary transfer roller pressure welding alienation
• During a retraction operation of the 2nd image transfer roller, the 2nd image transfer welding alienation sensor cannot detect the 2nd image transfer roller at its retracted position within a predetermined period of time after the 2nd image transfer retraction motor starts rotating. • During a pressure operation of the 2nd image transfer roller, the 2nd image transfer welding alienation sensor cannot detect the 2nd image transfer roller at its pressed position within a predetermined period of time after the 2nd image transfer retraction motor starts rotating.

Remedy:

1 Check the M16 connector for proper connection and correct as necessary. 2 Check the connector of M16 for proper drive coupling and correct as necessary. 3 PS36 I/O check, sensor check. 4 Change the right door assy. 5 Change PRCB.

 

Code: C2152

 

Description:

Transfer belt pressure welding alienation
• During a retraction operation of the transfer belt, the transfer belt retraction sensor cannot detect the transfer belt at its retracted position within a predetermined period of time after the transfer belt retraction clutch is turned ON. • During a pressure operation of the transfer belt, the transfer belt retraction sensor cannot detect the transfer belt at its pressed position within a predetermined period of time after the transfer belt clutch is turned ON.

Remedy:

1 Check the M5 connector for proper connection and correct as necessary. 2 PS31 I/O check, sensor check. 3 CL7 operation check. 4 M5 operation check. 5 Change CL7. 6 Change M21. 7 Change PRCB.

 

Code: C2164

 

Description:

PC charge malfunction
• When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time.

Remedy:

1 Check the imaging unit for proper connection and correct as necessary. 2 Check the HV connector for proper connection and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 Change IU. 5 Change HV. 6 Change PRCB.

 

Code: C2253

 

Description:

Color PC motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.

Remedy:

1 Check the M2 connector for proper connection and correct as necessary. 2 Check the M2 connector for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M2 operation check. 5 Change M2. 6 Change PRCB.

 

Code: C2254

 

Description:

Color PC motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.

Remedy:

1 Check the M2 connector for proper connection and correct as necessary. 2 Check the M2 connector for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M2 operation check. 5 Change M2. 6 Change PRCB

 

Code: C225D

 

Description:

Color dev. unit engagement/disengagement failure
• The gears remain disengaged after the lapse of a predetermined period of time after the engagement operation is started by the color dev. unit engaged motor. • The gears remain engaged after the lapse of a predetermined period of time after the disengagement operation is started by the color dev. unit engaged motor.

Remedy:

1 Check the M10 connector for proper connection and correct as necessary. 2 Check the M10 connector for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 PS26 I/O check, sensor check. 5 M10 operation check. 6 Change M10. 7 Change PRCB.

 

Code: C2351

 

Description:

K toner suction fan motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.

Remedy:

1 Check the FM3 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM3 operation check. 4 Change FM3. 5 Change PRCB.

 

Code: C2451

 

Description:

Release new transfer belt unit
• A new installation is not detected when a new transfer cleaner unit (image transfer belt unit) is installed.

Remedy:

1 Reinstall unit. 2 Check there is a short circuit in the fuse of the transfer belt unit. 3 Check the PRCB connector for proper connection and correct as necessary. 4 Change PRCBCB

 

Code: C2551

 

Description:

Abnormally low toner density detected cyan TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 4 % or less for a given number of times consecutively.

Remedy:

1 Reinstall imaging unit. 2 Reinstall toner cartridge. 3 M3, M4 operation check (At this time, IU must be non-installation.). 4 Change imaging unit. 5 Change PRCB.

 

Code: C2552

 

Description:

Abnormally high toner density detected cyan TCR sensor
• TC ratio in the developing machine, which is determined by Toner replenishing amount control mechanism, is 11 % or more for a given number of times consecutively.

Remedy:

1 Reinstall imaging unit. 2 Reinstall toner cartridge. 3 Change imaging unit. 4 Change PRCB.

 

Code: C2553

 

Description:

Abnormally low toner density detected magenta TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 4 % or less for a given number of times consecutively.

Remedy:

1 Reinstall imaging unit. 2 Reinstall toner cartridge. 3 M3, M4 operation check (At this time, IU must be non-installation.). 4 Change imaging unit. 5 Change PRCB.

 

Code: C2554

 

Description:

Abnormally high toner density detected magenta TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 11 % or more for a given number of times consecutively. • When the connector of the TCR sensor is disconnected.

Remedy:

1 Reinstall imaging unit. 2 Reinstall toner cartridge. 3 M3, M4 operation check (At this time, IU must be non-installation.). 4 Change imaging unit. 5 Change PRCB

 

Code: C2555

 

Description:

Abnormally low toner density detected yellow TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 4 % or less for a given number of times consecutively. • When the connector of the TCR sensor is disconnected.

Remedy:

.1 Reinstall imaging unit. 2 Reinstall toner cartridge. 3 Change imaging unit. 4 Change PRCB.

Code: C2556

 

Description:

Abnormally high toner density detected yellow TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 11 % or more for a given number of times consecutively. • When the connector of the TCR sensor is disconnected.

Remedy:

1 Reinstall imaging unit. 2 Reinstall toner cartridge. 3 M3, M4 operation check (At this time, IU must be non-installation.). 4 Change imaging unit. 5 Change PRCB

 

Code: C2557

 

Description:

Abnormally low toner density detected black TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 4 % or less for a given number of times consecutively.

Remedy:

1 M3 operation check (At this time, IU must be non-installation.) 2 Reinstall imaging unit. 3 Reinstall toner cartridge. 4 Change imaging unit /K. 5 Change PRCB.

 

Code: C2558

 

Description:

Abnormally high toner density detected black TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 11 % or more for a given number of times consecutively. • When the connector of the TCR sensor is disconnected.

Remedy:

1 Reinstall imaging unit. 2 Reinstall toner cartridge. 3 Change imaging unit. 4 Change PRCB.

 

Code: C2559

 

Description:

Cyan TCR sensor adjustment failure
• TCR sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.

Remedy:

1 Reinstall imaging unit. 2 Change imaging unit. 3 Change PRCB.

 

Code: C255A

 

Description:

Magenta TCR sensor adjustment failure

Remedy:

1 Reinstall imaging unit. 2 Change imaging unit. 3 Change PRCB.

 

Code: C255B

 

Description:

Yellow TCR sensor adjustment failure

Remedy:

1 Reinstall imaging unit. 2 Change imaging unit. 3 Change PRCB.

 

Code: C255C

 

Description:

Black TCR sensor adjustment failure

Remedy:

1 Reinstall imaging unit /K. 2 Change imaging unit /K. 3 Change PRCB.